Øverst på siden

DSH101CRT PTC 2/2 VENTIL NCMan. override

Varenr. 100117
Parker’s 2-way poppet solenoid valves check flow in one direction free flow opposite; normally-open or normally-closed configurations available. Capable of pressures up to 350 bar (5000 psi) and flows up to 260 lpm (70 gpm). Low leakage Produktspesifikasjoner Part Number DSH101CRT Brand Parker Confi
Pris kr8431.8
Pris pr pk STK
Uten MVA
På lager
STK

Beskrivelse

Parker’s 2-way poppet solenoid valves check flow in one direction free flow opposite; normally-open or normally-closed configurations available. Capable of pressures up to 350 bar (5000 psi) and flows up to 260 lpm (70 gpm). Low leakage

Produktspesifikasjoner


Part NumberDSH101CRTBrandParker
ConfigurationNormally ClosedFlow DirectionSide to Nose (2-1)
DivisionHydraulic Cartridge Systems DivisionFree Reverse FlowYes
Function2-wayOverride FunctionalityPush and Twist
Wire Mesh Screen IncludedNoSeal MaterialD-Ring (Standard)
Valve MaterialAll parts steel. All operating parts hardened steelMaximum Operating Pressure350 bar | 5000 psi
Flow Rate15 GAL/MIN, 60 L/MIN | 15 Gal/min | 60 L/minMaximum Flow Rate15 Gal/min | 60 L/min
Leak Rate5 drops/minMaximum Inlet Pressure Rating350 bar | 5000 PSI, 350 BAR | 5000 psi
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Cavity SizeC10-2
Minimum Operating Temperature-35 °F | -37 °CMaximum Operating Temperature+93 °C | +200 °F
Operating Temperature-35 to +200 °F | -37 to +93 °CResponse Time80 ms
Installation Torque51-55 lb-ft | 69-75 NmCoil Nut Tightening Torque5-7 lb-ft | 7-10 Nm
Actuation TypeElectrical, ManualMounting TypeScrew in cartridge valve
For Fluid TypeMineral-based or synthetic hydraulic fluidsOperation TypeSolenoid operated, Manually operated
Coil Type5/8" Super CoilMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Input Voltage85% of rated voltage at 72°F (20°C) minWeight0.2 kg | 0.41 lb

Spesifikasjoner

Leverandørs varenr.
DSH101CRT
Beregning av leveringstid
167D
Tariffnr.
84812010
Opprinnelsesland/-område - kode
United States

DSH101CRT PTC 2/2 VENTIL NCMan. override

Varenr. 100117
Parker’s 2-way poppet solenoid valves check flow in one direction free flow opposite; normally-open or normally-closed configurations available. Capable of pressures up to 350 bar (5000 psi) and flows up to 260 lpm (70 gpm). Low leakage Produktspesifikasjoner Part Number DSH101CRT Brand Parker Confi
Pris kr8431.8
Pris pr pk STK
Uten MVA
På lager
Laster
STK

Beskrivelse

Parker’s 2-way poppet solenoid valves check flow in one direction free flow opposite; normally-open or normally-closed configurations available. Capable of pressures up to 350 bar (5000 psi) and flows up to 260 lpm (70 gpm). Low leakage

Produktspesifikasjoner


Part NumberDSH101CRTBrandParker
ConfigurationNormally ClosedFlow DirectionSide to Nose (2-1)
DivisionHydraulic Cartridge Systems DivisionFree Reverse FlowYes
Function2-wayOverride FunctionalityPush and Twist
Wire Mesh Screen IncludedNoSeal MaterialD-Ring (Standard)
Valve MaterialAll parts steel. All operating parts hardened steelMaximum Operating Pressure350 bar | 5000 psi
Flow Rate15 GAL/MIN, 60 L/MIN | 15 Gal/min | 60 L/minMaximum Flow Rate15 Gal/min | 60 L/min
Leak Rate5 drops/minMaximum Inlet Pressure Rating350 bar | 5000 PSI, 350 BAR | 5000 psi
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Cavity SizeC10-2
Minimum Operating Temperature-35 °F | -37 °CMaximum Operating Temperature+93 °C | +200 °F
Operating Temperature-35 to +200 °F | -37 to +93 °CResponse Time80 ms
Installation Torque51-55 lb-ft | 69-75 NmCoil Nut Tightening Torque5-7 lb-ft | 7-10 Nm
Actuation TypeElectrical, ManualMounting TypeScrew in cartridge valve
For Fluid TypeMineral-based or synthetic hydraulic fluidsOperation TypeSolenoid operated, Manually operated
Coil Type5/8" Super CoilMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Input Voltage85% of rated voltage at 72°F (20°C) minWeight0.2 kg | 0.41 lb

Spesifikasjoner

Leverandørs varenr.
DSH101CRT
Beregning av leveringstid
167D
Tariffnr.
84812010
Opprinnelsesland/-område - kode
United States